Information presented on this page is intended to demonstrate the section design convergence that can be achived with SkyCiv. All examples are taken from:
Design Case | Manual | SkyCiv |
---|---|---|
Factored compressive resistance Cr, kN | 2880.00 | 2878.03 |
Design Case | Manual | SkyCiv |
---|---|---|
Factored compressive resistance Cr, kN | 529.00 | 526.36 |
Design Case | Manual | SkyCiv |
---|---|---|
Factored compressive resistance Cr, kN | 15700.00 | 15664.05 |
Design Case | Manual | SkyCiv |
---|---|---|
Factored moment resistance Mrz, kN-m | 100.00 | 100.23 |
Design Case | Manual | SkyCiv |
---|---|---|
Factored moment resistance Mrz, kN-m | 297.00 | 296.51 |
Design Case | Manual | SkyCiv |
---|---|---|
Factored moment resistance Mrz, kN-m | 649.00 | 648.90 |
Design Case | Manual | SkyCiv |
---|---|---|
Nominal section moment capacity Cr, kN | 2200.00 | 2217.12 |
Nominal section moment capacity Mrz, kN-m | 310.00 | 310.28 |
Interaction ratio of combined axial compression and bending resistance | 0.930 | 0.926 |
Design Case | Manual | SkyCiv |
---|---|---|
Nominal section moment capacity Cr, kN | 4240.00 | 4241.90 |
Nominal section moment capacity Mrz, kN-m | 671.00 | 670.68 |
Nominal section moment capacity Mry, kN-m | 308.00 | 307.71 |
Interaction ratio of combined axial compression and bending resistance | 0.990 | 1.030 |